Cooling Tower is a kind of Heat-Exchangers
to cool down heat medium such as water by contacting
it to the atmosphere directly or indirectly.
We have been making progress as a leading company
in the air-conditioning field since we granted our
first patent for axial flow type Cooling Tower.
In addition to the Cooling Tower for air-conditioning
application(overwhelming market share domestically),
we have been supplying large-scale Cooling Tower
for Industrial use to many plant facilities.
We also focus on the product development corresponding
to the customer's need with Low Noise,Energy Saving
& Plume-Abatement type. Our effort to consider
the requirement has come to good as follows:
ISO 9001 certification in 1998.
ISO 14001 certification in 2001. |
|
 |
ythe feature of a Kuken Cooling Towerz
|
¡Save time for total construction
schedule with Unit-Shipment |
In order to minimize the time for
site-erection, Kuken Cooling Tower is delivered
in a semi-assembled form.
It also helps reduce the waste material used for
packing dramatically.
But conventional Complete Knock-down Shipment is
also available if requested. |
| ¡Variety of Cooling Tower adapted to
environment |
To cope with requirement at site,
following three types are available :
Low Noise type
Super Low Noise type
Energy-Saving & super-low noise type
If further noise reduction is requested, tower
adopting Aero Foil Fan(patent pending, design patent
granted) is the ultimate solution.
|
|
| |
An Open type cools down the circulation
water by contacting it to the atmosphere directly
maximizing latent heat effect.
Compared to a Closed type, an Open Type features
high-efficiency, compact in size, easier maintenance,
and lower initial cost. |
¡Development applying new technology
brings high-efficiency |
ETower becomes compact in size thanks
to the newly developed Filling and Fan Unit.
ENewly developed Filling minimizes drift-loss rate.
EFurther noise reduction can be expected due to performance
of Newly developed Fan Unit.
EMore durable in consequence of adopting the most
appropreate metal parts with additional galvanizing. |
| ¡Maintenance made simple |
| Inclined Lower Basin with Inspection
Board, Internal Piping made maintenance & cleaning
work simple. |
|
| |
yClosed type Cooling
Towerz |
|
 |
Closed type Cooling Tower differs
from an Open type in the sense that circulating
water runs only inside a totally enclosed copper
tube and it never contacts ambient air. Due to this
fact, water quality control made simple. |
|
| |
áfeatureâ |
¡high protectability |
Polluted air sucked into the tower,
scale and slime generated by over-concentration
and poor quality of water are attributed to be the
cause of mechanical trouble.
It is not only the problem for cooling tower but
also for the related equipments used in the whole
system.
With Closed type cooling tower, whole cooling system
is totally protected against water-related trouble.
|
| ¡ reasonable total cost |
* Save expense for circulating
water : no refill nor replenishing of circ. water
required.
* Save total maintenance & cleaning cost for
entire cooling system including chiller & piping.
|
|
|